GDBZ-III Transformer Comprehensive Test Bench

Comprehensive test bench for 10 kV and 35 kV class power transformers, covering no-load and load tests, induced withstand voltage and power-frequency applied withstand voltage. Primary side voltage class below 35 kV.

GDBZ-III Transformer Comprehensive Test Bench

Overview

Comprehensive test bench for 10 kV and 35 kV class power transformers, covering no-load and load tests, induced withstand voltage and power-frequency applied withstand voltage. Primary side voltage class below 35 kV.

Application Scenarios

No-load and load tests on 10 kV transformersNo-load and load tests on 35 kV transformersInduced and applied power-frequency withstand voltage tests

Request Specifications & Quotation

Tell us your test object ratings, the test items you need and the applicable standards. Our sales engineers reply with a configuration proposal and a formal quotation within 24 hours.

Get a Quote

Detailed Description

Service conditions: the equipment is to be used at an installation altitude not exceeding 1000 m. The ambient medium temperature is not higher than +40 °C and not lower than -5 °C, and the relative air humidity is not higher than 85%. It is to be used where there is no conductive dust and no gas corrosive to metal or insulation, where there is no explosion hazard, and where there is no vibration and the vertical inclination does not exceed 5°.

Transformer under test: capacity is up to 2500 kVA at the 10 kV class and up to 31500 kVA at the 35 kV class (with the optional capacitor compensation cabinet). The voltage class on the primary side of the transformer under test is below 35 kV.

Measuring accuracy: voltage range 0-22 kV (for 35 kV class power transformers) and current range 0-400 A (extendable). Minimum voltage resolution is 0.001 V × PT ratio, minimum current resolution is 0.0001 A × CT ratio and minimum power resolution is 0.1 W × PT ratio × CT ratio. Ambient operating temperature is -10 to 45 °C and ambient operating relative humidity is 85%.

Test items: 10 kV transformer no-load test, completing no-load loss and no-load current (%) measurement; 10 kV transformer load test, completing load loss and impedance voltage (%) measurement; 35 kV transformer no-load test, completing no-load loss and no-load current (%) measurement; 35 kV transformer load test, completing load loss and impedance voltage (%) measurement; transformer induced withstand voltage test, completing the turn-to-turn, layer-to-layer and section-to-section insulation tests; and transformer power-frequency withstand voltage test, completing the applied withstand voltage test. Extendable test items are partial discharge testing of dry-type transformers and transformer temperature-rise testing.

Technical Specifications

Transformer capacity under test — 10 kV class≤2500KVA
Transformer capacity under test — 35 kV class≤31500kVA (with optional capacitor compensation cabinet)
Transformer voltage class under test — primary sideBelow 35kV
Voltage range0-22kV (35KV class power transformer)
Current range0-400A (extendable)
Minimum voltage resolution0.001V*PT ratio
Minimum current resolution0.0001A*CT ratio
Minimum power resolution0.1W*PT ratio*CT ratio
Ambient operating temperature-10~45℃
Ambient operating relative humidity85%
Installation altitudeNot exceeding 1000 m
Ambient medium temperatureNot higher than +40℃, not lower than -5℃
Vertical inclinationNot exceeding 5°
BrandGaodian Electric

Frequently Asked Questions

What is the GDBZ-III Transformer Comprehensive Test Bench used for?
It performs no-load tests on 10 kV and 35 kV transformers (no-load loss and no-load current %), load tests on 10 kV and 35 kV transformers (load loss and impedance voltage %), transformer induced withstand voltage tests covering turn-to-turn, layer-to-layer and section-to-section insulation, and transformer power-frequency withstand voltage tests, i.e. applied withstand voltage tests. Extendable items are partial discharge testing of dry-type transformers and transformer temperature-rise testing.
What service conditions does the bench require?
The equipment is to be used at an installation altitude not exceeding 1000 m, with ambient medium temperature not higher than +40 °C and not lower than -5 °C, relative air humidity not higher than 85%, in a place free of conductive dust and of gases corrosive to metal and insulation, free of explosion hazard, and free of vibration with vertical inclination not exceeding 5°.
How do I get a quotation?
Email your transformer capacity and voltage classes, and whether you need the optional capacitor compensation cabinet, to bowen@harchin.com. Benches are manufactured in our Nanjing facility and quoted directly from the factory.

Need the datasheet for this model?

Send us this product name plus your test requirements. We reply with specifications, photos and a formal quotation.