Transformer Testing
GD-400A Transformer Capacity & No-Load Loss Tester
Measures the capacity and load loss of 30 kVA to 63000 kVA power transformers on site without any external supply or auxiliary equipment. Supports waveform distortion, temperature, voltage and current correction.

Overview
Measures the capacity and load loss of 30 kVA to 63000 kVA power transformers on site without any external supply or auxiliary equipment. Supports waveform distortion, temperature, voltage and current correction.
Standards & Compliance
Benchmark standards for this equipment category
Systems in this category are commonly specified against these standards, linked to the issuing body. Final configuration and acceptance criteria follow the standard and edition you nominate.
- IEC 60076-1 — Power transformers - General
- IEC 60076-3 — Insulation levels and dielectric tests
- IEC 60076-5 — Ability to withstand short circuit
- IEEE C57.12.90 — Test code for liquid-immersed distribution and power transformers
- GB 1094 — Power transformers
- GB 50150 — Hand-over test of electrical equipment
Application Scenarios
Request Specifications & Quotation
Tell us your test object ratings, the test items you need and the applicable standards. Our sales engineers reply with a configuration proposal and a formal quotation within 24 hours.
Get a QuoteDetailed Description
Overview: on site, and without any external power supply (neither 220 V nor 380 V) or any auxiliary equipment, the instrument measures the capacity and load loss of 30 kVA to 63000 kVA power transformers.
Key features: it accurately measures the capacity of all types of distribution transformer, using passive measurement that is convenient and accurate. It measures no-load current, no-load loss, short-circuit voltage, short-circuit loss and zero-sequence impedance of various transformer types. Waveform distortion correction, temperature correction, voltage correction (for no-load tests at other than rated voltage) and current correction (for short-circuit tests at other than rated current) are performed automatically; the operator only enters the correction index for the transformer type and the instrument calculates the corrected result, which is well suited to organisations without the facilities for short-circuit tests on larger transformers. External voltage and current transformers can be connected to extend the measuring range, so test objects with any parameters can be measured.
The voltage circuit is wide-limit: voltage can be measured up to 750 V with no range switching and no loss of accuracy, so a wrongly selected voltage range cannot damage the instrument. The large, high-brightness LCD with full Chinese menus and operating prompts provides a friendly operator dialogue; touch keys simplify operation and the wide-temperature LCD with brightness adjustment suits both winter and summer use. Results can be printed out at any time on the micro printer.
Insulation: the insulation resistance between the voltage and current input terminals and the case is ≥100 MΩ, and the working supply input terminal withstands power-frequency 2 kV (RMS) against the case for 1 minute.
Technical Specifications
| Active part — voltage measuring range | 0~10V |
|---|---|
| Active part — current measuring range | 0~10A |
| Passive part — voltage measuring range | 0~750V wide-limit |
| Passive part — current measuring range | 0~100A, all ranges switched automatically |
| Capacity measuring range | 30KVA-63000KVA |
| Accuracy — voltage, current, frequency | ±0.2% |
| Accuracy — capacity | ±10% |
| Operating temperature | -10℃~+40℃ |
| Working supply | AC 160V~240V |
| Insulation resistance | ≥100MΩ between voltage/current input terminals and case |
| Dielectric strength | Working supply input to case withstands power-frequency 2KV (RMS) for 1 minute |
| Dimensions | 32cm×24cm×13cm |
| Weight | 3Kg |
| Brand | Gaodian Electric |
Frequently Asked Questions
What is the GD-400A Transformer Capacity & No-Load Loss Tester used for?
What corrections does the instrument apply automatically?
How do I get a quotation?
Further Reading
Method and selection guides that cover the tests this instrument performs.
Reviewed by the Application Engineering Team at Nanjing Gaodian Electric Power Equipment
Specifications are taken from the manufacturer’s technical documentation. Final configuration and acceptance criteria follow the standard and edition you nominate — tell us your test list and we will confirm the ratings.
Related Products

ECBZ-GD Energy-Efficient Transformer Energy-Grade Evaluation System
Automatic evaluation system for the energy-efficiency grade of distribution transformers up to 800 kVA at 10 kV/0.4 kV. Combines intelligent test sequence control, automatic wiring changeover, data processing, data upload and report generation in one bench.

GD230 Ground Continuity Tester
Portable instrument for measuring the continuity resistance between the grounding down conductors of individual items of equipment in a substation. Controlled by a high-performance MCU with automatic current selection, on-board data retention and a thermal printer.

GD-300B Transformer Short-Circuit Impedance Tester
Measures transformer short-circuit impedance, short-circuit reactance, short-circuit resistance and three-phase impedance voltage. Uses dual A/D synchronous AC sampling and DSP for winding deformation assessment in the field.

GD-300D Reactor Electrical Parameter Tester (Portable)
Portable instrument dedicated to measuring the electrical parameters of single-phase and three-phase reactors, including AC phase voltage RMS, average voltage, current RMS, active power, reactance and inductance, at 0.5 class accuracy.

DC Winding Resistance Tester
Portable instrument for DC resistance measurement of inductive equipment such as transformers, motors and instrument transformers (CT/PT). Fully software-controlled with back-EMF protection and field anti-interference capability.

GD-300D Reactor Electrical Parameter Tester (Built-in)
Panel-mounted version of the GD-300D reactor electrical parameter tester, using a 320 x 240 dot-matrix LCD with multi-screen menu operation and direct measurement of three-phase reactance, inductance and total active power.
More in Transformer Testing
- •ECBZ-GD Energy-Efficient Transformer Energy-Grade Evaluation System
- •GD-300B Transformer Short-Circuit Impedance Tester
- •DC Winding Resistance Tester
- •GDBZ-IV Transformer Test Bench
- •GDBZ-III Transformer Comprehensive Test Bench
- •Transformer Intelligent Logistics Line Test System
- •GDBZ-IV 220/110kV Main Transformer Comprehensive Test System
- •GDBZ-IV Automatic Transformer Comprehensive Test System
- •GD700A Automatic Turns Ratio Tester
- •GDRZ Transformer Winding Deformation Tester
- •GD-810 Transformer On-Load Tap-Changer Tester
- •GD200-40WA Dual-Channel DC Winding Resistance Tester
- •GD300C Power Analyzer
- •GD-700 Automatic Turns Ratio & Vector-Group Tester
Need the datasheet for this model?
Send us this product name plus your test requirements. We reply with specifications, photos and a formal quotation.