Transformer Testing
ECBZ-GD Energy-Efficient Transformer Energy-Grade Evaluation System
Automatic evaluation system for the energy-efficiency grade of distribution transformers up to 800 kVA at 10 kV/0.4 kV. Combines intelligent test sequence control, automatic wiring changeover, data processing, data upload and report generation in one bench.

Overview
Automatic evaluation system for the energy-efficiency grade of distribution transformers up to 800 kVA at 10 kV/0.4 kV. Combines intelligent test sequence control, automatic wiring changeover, data processing, data upload and report generation in one bench.
Application Scenarios
Request Specifications & Quotation
Tell us your test object ratings, the test items you need and the applicable standards. Our sales engineers reply with a configuration proposal and a formal quotation within 24 hours.
Get a QuoteDetailed Description
Overview: the system provides all of the functions of intelligent test sequence control, intelligent wiring changeover, intelligent data processing, intelligent data upload and intelligent report generation. It comprises an intelligent measurement module, a power distribution module, an automatic wiring-changeover module and a wiring indication module. It supports intelligent interconnection and automatic interlocking with an intelligent safety fence, and it provides input protection, output protection and zero-position start protection. Voltage, current and power are under closed-loop automatic regulation.
Test capability: the system measures the energy-efficiency grade of distribution transformers rated 800 kVA and below, at voltage classes of 10 kV/0.4 kV.
Measuring range covers voltage 0-800V (extendable to 1200V), current on the 50 A channel 0-5/50 A (extendable to 200 A), and frequency 45 Hz-65 Hz. Measuring accuracy is ±(0.1% of reading + 0.1% of range) for voltage, ±(0.1% of reading + 0.1% of range) for current, ±(0.2% of reading + 0.2% of range) for power, ±(0.2% of reading + 0.2% of range) for power factor and ±(0.25% of reading + 0.25% of range) for frequency.
Construction: the system is built from a standardised set of modules — intelligent measurement, power distribution, automatic wiring changeover and wiring indication — installed in a single enclosure measuring 1500 x 1200 x 1300 and weighing approximately 350 kg, powered from 380 V ±5%.
Expansion capability: distribution transformers below 2500 kVA/10 kV and power transformers below 6300 kVA/35 kV.
Technical Specifications
| Test capability | Energy-grade measurement of distribution transformers 800 kVA and below; voltage class 10 kV/0.4 kV |
|---|---|
| Voltage measuring range | 0-800V (extendable to 1200V) |
| Current measuring range | 50A channel 0-5/50A (extendable to 200A) |
| Frequency measuring range | 45Hz-65Hz |
| Voltage accuracy | ±(0.1% reading + 0.1% range) |
| Current accuracy | ±(0.1% reading + 0.1% range) |
| Power accuracy | ±(0.2% reading + 0.2% range) |
| Power factor accuracy | ±(0.2% reading + 0.2% range) |
| Frequency accuracy | ±(0.25% reading + 0.25% range) |
| Power supply | 380V±5% |
| Dimensions | 1500*1200*1300 |
| Weight | Approx. 350KG |
| Expansion capability | Distribution transformers below 2500kVA/10kV; power transformers below 6300kVA/35kV |
| Brand | Gaodian Electric |
| Type | GDBZ |
Frequently Asked Questions
What is the ECBZ-GD Energy-Efficient Transformer Energy-Grade Evaluation System used for?
What protection functions does the system provide?
How do I get a quotation?
Related Products

GD-300B Transformer Short-Circuit Impedance Tester
Measures transformer short-circuit impedance, short-circuit reactance, short-circuit resistance and three-phase impedance voltage. Uses dual A/D synchronous AC sampling and DSP for winding deformation assessment in the field.

DC Winding Resistance Tester
Portable instrument for DC resistance measurement of inductive equipment such as transformers, motors and instrument transformers (CT/PT). Fully software-controlled with back-EMF protection and field anti-interference capability.

GD-400A Transformer Capacity & No-Load Loss Tester
Measures the capacity and load loss of 30 kVA to 63000 kVA power transformers on site without any external supply or auxiliary equipment. Supports waveform distortion, temperature, voltage and current correction.
Need the datasheet for this model?
Send us this product name plus your test requirements. We reply with specifications, photos and a formal quotation.