Transformer Testing
GD-810 Transformer On-Load Tap-Changer Tester
Measures transition time, transition waveform, transition resistance and three-phase synchronism of on-load tap-changers on transformers with or without a neutral point, without lifting the core.

Overview
Measures transition time, transition waveform, transition resistance and three-phase synchronism of on-load tap-changers on transformers with or without a neutral point, without lifting the core.
Standards & Compliance
Benchmark standards for this equipment category
Systems in this category are commonly specified against these standards, linked to the issuing body. Final configuration and acceptance criteria follow the standard and edition you nominate.
- IEC 60076-1 — Power transformers - General
- IEC 60076-3 — Insulation levels and dielectric tests
- IEC 60076-5 — Ability to withstand short circuit
- IEEE C57.12.90 — Test code for liquid-immersed distribution and power transformers
- GB 1094 — Power transformers
- GB 50150 — Hand-over test of electrical equipment
Application Scenarios
Request Specifications & Quotation
Tell us your test object ratings, the test items you need and the applicable standards. Our sales engineers reply with a configuration proposal and a formal quotation within 24 hours.
Get a QuoteDetailed Description
Overview: the GD-810 features a large-screen LCD with human-machine dialogue operation, and prints and stores test results. It is suitable for on-load transformers with or without a neutral-point lead-out, and requires no core lifting.
Measurement capability: it measures the transition time, transition waveform, transition resistance and three-phase synchronism of on-load tap-changers.
Technical parameters: it uses a three-phase test supply with 0.5 A output current, a sampling frequency of 10-20 kHz and a single-waveform storage time of 6.4 seconds. The synchronism error is 0.2 ms and the power supply is AC220V±10%, 50Hz±2%.
Technical Specifications
| Test supply | Three-phase, output current 0.5A |
|---|---|
| Sampling frequency | 10-20kHz |
| Single waveform storage time | 6.4s |
| Transition resistance (Y/O-type transformer) | ≤40Ω |
| Transition resistance (Y-type transformer) | ≤20Ω |
| Synchronism error | 0.2ms |
| Power supply | AC220V±10%, 50Hz±2% |
Frequently Asked Questions
What is the GD-810 Transformer On-Load Tap-Changer Tester used for?
What transformers can it test?
How do I get a quotation?
Reviewed by the Application Engineering Team at Nanjing Gaodian Electric Power Equipment
Specifications are taken from the manufacturer’s technical documentation. Final configuration and acceptance criteria follow the standard and edition you nominate — tell us your test list and we will confirm the ratings.
Related Products

ECBZ-GD Energy-Efficient Transformer Energy-Grade Evaluation System
Automatic evaluation system for the energy-efficiency grade of distribution transformers up to 800 kVA at 10 kV/0.4 kV. Combines intelligent test sequence control, automatic wiring changeover, data processing, data upload and report generation in one bench.

GD230 Ground Continuity Tester
Portable instrument for measuring the continuity resistance between the grounding down conductors of individual items of equipment in a substation. Controlled by a high-performance MCU with automatic current selection, on-board data retention and a thermal printer.

GD-300B Transformer Short-Circuit Impedance Tester
Measures transformer short-circuit impedance, short-circuit reactance, short-circuit resistance and three-phase impedance voltage. Uses dual A/D synchronous AC sampling and DSP for winding deformation assessment in the field.

GD-300D Reactor Electrical Parameter Tester (Portable)
Portable instrument dedicated to measuring the electrical parameters of single-phase and three-phase reactors, including AC phase voltage RMS, average voltage, current RMS, active power, reactance and inductance, at 0.5 class accuracy.

DC Winding Resistance Tester
Portable instrument for DC resistance measurement of inductive equipment such as transformers, motors and instrument transformers (CT/PT). Fully software-controlled with back-EMF protection and field anti-interference capability.

GD-300D Reactor Electrical Parameter Tester (Built-in)
Panel-mounted version of the GD-300D reactor electrical parameter tester, using a 320 x 240 dot-matrix LCD with multi-screen menu operation and direct measurement of three-phase reactance, inductance and total active power.
More in Transformer Testing
- •ECBZ-GD Energy-Efficient Transformer Energy-Grade Evaluation System
- •GD-300B Transformer Short-Circuit Impedance Tester
- •DC Winding Resistance Tester
- •GD-400A Transformer Capacity & No-Load Loss Tester
- •GDBZ-IV Transformer Test Bench
- •GDBZ-III Transformer Comprehensive Test Bench
- •Transformer Intelligent Logistics Line Test System
- •GDBZ-IV 220/110kV Main Transformer Comprehensive Test System
- •GDBZ-IV Automatic Transformer Comprehensive Test System
- •GD700A Automatic Turns Ratio Tester
- •GDRZ Transformer Winding Deformation Tester
- •GD200-40WA Dual-Channel DC Winding Resistance Tester
- •GD300C Power Analyzer
- •GD-700 Automatic Turns Ratio & Vector-Group Tester
Need the datasheet for this model?
Send us this product name plus your test requirements. We reply with specifications, photos and a formal quotation.