Transformer Testing

GD300C Power Analyzer

Measures RMS voltage, average voltage, RMS current, active power, power factor and frequency of single- or three-phase power transformers, per JB/T 501 and GB 1094, at 0.5 accuracy class.

GD300C Power Analyzer

Overview

Measures RMS voltage, average voltage, RMS current, active power, power factor and frequency of single- or three-phase power transformers, per JB/T 501 and GB 1094, at 0.5 accuracy class.

Standards & Compliance

Cited in this product’s specification

Benchmark standards for this equipment category

Systems in this category are commonly specified against these standards, linked to the issuing body. Final configuration and acceptance criteria follow the standard and edition you nominate.

Application Scenarios

Transformer no-load testTransformer load testTransformer induction testReplacement for pointer-type instruments

Request Specifications & Quotation

Tell us your test object ratings, the test items you need and the applicable standards. Our sales engineers reply with a configuration proposal and a formal quotation within 24 hours.

Get a Quote

Detailed Description

Overview: the GD-300C electrical parameter measuring instrument meets JB/T 501-91 and GB 1094-96. It measures the RMS voltage, average voltage, RMS current, active power, power factor and frequency of single-phase or three-phase power transformers at the same time, at 0.5 accuracy class.

Display: a 240x64 dot-matrix backlit LCD displays 18 electrical parameters simultaneously - single- or three-phase RMS voltage, average voltage, RMS current, active power, power factor and frequency - with a multi-screen menu for easy operation.

Computation and calibration: it automatically calculates parameters such as P0, I0, Pkn, ekt, ek75°C and Zk, and automatically corrects voltage amplitude, waveform and temperature. CT/PT ratios are key-settable to display primary values directly.

Interfaces: it includes a printer port and a serial RS232 computer interface, with strong anti-interference, overload alarm, and reliable over-voltage and over-current protection for field calibration environments.

Technical Specifications

Measurement parametersRMS voltage, average voltage, RMS current, active power, power factor, frequency (18 parameters)
Accuracy class0.5
Display240x64 dot-matrix backlit LCD
Auto-computed parametersP0, I0, Pkn, ekt, ek75°C, Zk
InterfacesPrinter port, RS232 computer interface
StandardsJB/T 501-91, GB 1094-96

Frequently Asked Questions

What is the GD300C Power Analyzer used for?
It measures the RMS voltage, average voltage, RMS current, active power, power factor and frequency of single-phase or three-phase power transformers at the same time, and is suitable for transformer no-load, load and induction tests.
What standards does it comply with?
It is designed to the technical requirements of JB/T 501-91 (Power Transformer Test Guide) and GB 1094-96 (Power Transformers), with a measurement accuracy of 0.5 class.
How do I get a quotation?
Email your transformer ratings and test requirements to bowen@harchin.com. The instrument is manufactured in our Nanjing facility and quoted directly from the factory based on your configuration.

Reviewed by the Application Engineering Team at Nanjing Gaodian Electric Power Equipment

Specifications are taken from the manufacturer’s technical documentation. Final configuration and acceptance criteria follow the standard and edition you nominate — tell us your test list and we will confirm the ratings.

Related Products

ECBZ-GD Energy-Efficient Transformer Energy-Grade Evaluation System
Transformer Testing

ECBZ-GD Energy-Efficient Transformer Energy-Grade Evaluation System

Automatic evaluation system for the energy-efficiency grade of distribution transformers up to 800 kVA at 10 kV/0.4 kV. Combines intelligent test sequence control, automatic wiring changeover, data processing, data upload and report generation in one bench.

GD230 Ground Continuity Tester
Power Testing Instruments

GD230 Ground Continuity Tester

Portable instrument for measuring the continuity resistance between the grounding down conductors of individual items of equipment in a substation. Controlled by a high-performance MCU with automatic current selection, on-board data retention and a thermal printer.

GD-300B Transformer Short-Circuit Impedance Tester
Transformer Testing

GD-300B Transformer Short-Circuit Impedance Tester

Measures transformer short-circuit impedance, short-circuit reactance, short-circuit resistance and three-phase impedance voltage. Uses dual A/D synchronous AC sampling and DSP for winding deformation assessment in the field.

GD-300D Reactor Electrical Parameter Tester (Portable)
Reactor & Arc Suppression Coil Testing

GD-300D Reactor Electrical Parameter Tester (Portable)

Portable instrument dedicated to measuring the electrical parameters of single-phase and three-phase reactors, including AC phase voltage RMS, average voltage, current RMS, active power, reactance and inductance, at 0.5 class accuracy.

DC Winding Resistance Tester
Transformer Testing

DC Winding Resistance Tester

Portable instrument for DC resistance measurement of inductive equipment such as transformers, motors and instrument transformers (CT/PT). Fully software-controlled with back-EMF protection and field anti-interference capability.

GD-300D Reactor Electrical Parameter Tester (Built-in)
Reactor & Arc Suppression Coil Testing

GD-300D Reactor Electrical Parameter Tester (Built-in)

Panel-mounted version of the GD-300D reactor electrical parameter tester, using a 320 x 240 dot-matrix LCD with multi-screen menu operation and direct measurement of three-phase reactance, inductance and total active power.

Need the datasheet for this model?

Send us this product name plus your test requirements. We reply with specifications, photos and a formal quotation.