High Voltage Test Equipment

Three-Phase Isolation Filter

Three-phase isolation filter rated 30 kVA at 0 to 800 V and 22 A, covering 0 to 200 Hz with attenuation of 60 dB or better from 10 kHz to 300 kHz and a partial discharge level of 3 pC or less at rated voltage. Supplied alongside the WF-100-0.001 non-partial-discharge coupling capacitor range.

Three-Phase Isolation Filter

Overview

Three-phase isolation filter rated 30 kVA at 0 to 800 V and 22 A, covering 0 to 200 Hz with attenuation of 60 dB or better from 10 kHz to 300 kHz and a partial discharge level of 3 pC or less at rated voltage. Supplied alongside the WF-100-0.001 non-partial-discharge coupling capacitor range.

Standards & Compliance

Benchmark standards for this equipment category

Systems in this category are commonly specified against these standards, linked to the issuing body. Final configuration and acceptance criteria follow the standard and edition you nominate.

Application Scenarios

Filtering the supply of partial discharge test circuitsAttenuating interference across the 10 kHz to 300 kHz bandCoupling capacitor selection for partial discharge measurement circuitsCustomised capacity and working voltage versions

Request Specifications & Quotation

Tell us your test object ratings, the test items you need and the applicable standards. Our sales engineers reply with a configuration proposal and a formal quotation within 24 hours.

Get a Quote

Detailed Description

Main technical parameters of the three-phase isolation filter: working voltage 0 to 800 V; rated current 22 A; rated capacity 30 kVA; frequency 0 to 200 Hz.

Attenuation is 60 dB or better from 10 kHz to 100 kHz and 60 dB or better from 100 kHz to 300 kHz. The partial discharge level is Q of 3 pC or less at rated voltage.

Note: the rated capacity and the working voltage of the isolation filter can be customised to the customer requirement.

WF-100-0.001 non-partial-discharge coupling capacitors: OWF60-0.001 at 60 kV and 1000 pF, 160 x 740 mm, 13 kg; OWF120-0.0005 at 120 kV and 500 pF, 160 x 900 mm, 28 kg; OWF100-0.001 at 100 kV and 1000 pF, 160 x 900 mm, 28 kg; OWF120-0.001 at 120 kV and 1000 pF, 160 x 900 mm, 28 kg; OWF150-0.002 at 150 kV and 2000 pF, 160 x 1300 mm, 29 kg; and OWF250-0.0005 at 250 kV and 500 pF, 160 x 2000 mm, 32 kg. Dimensions are given as diameter x height.

Technical Specifications

Working voltage0 – 800 V
Rated current22 A
Rated capacity30 kVA
Frequency0 – 200 Hz
Attenuation10 kHz – 100 kHz: 60 dB or better; 100 kHz – 300 kHz: 60 dB or better
Partial discharge levelQ of 3 pC or less at rated voltage
CustomisationRated capacity and working voltage customised to the customer requirement
Coupling capacitor OWF60-0.00160 kV, 1000 pF, diameter x height 160 x 740 mm, 13 kg
Coupling capacitor OWF120-0.0005120 kV, 500 pF, diameter x height 160 x 900 mm, 28 kg
Coupling capacitor OWF100-0.001100 kV, 1000 pF, diameter x height 160 x 900 mm, 28 kg
Coupling capacitor OWF120-0.001120 kV, 1000 pF, diameter x height 160 x 900 mm, 28 kg
Coupling capacitor OWF150-0.002150 kV, 2000 pF, diameter x height 160 x 1300 mm, 29 kg
Coupling capacitor OWF250-0.0005250 kV, 500 pF, diameter x height 160 x 2000 mm, 32 kg

Frequently Asked Questions

What are the main ratings of the three-phase isolation filter?
The working voltage is 0 to 800 V, the rated current is 22 A and the rated capacity is 30 kVA. The frequency range is 0 to 200 Hz.
What attenuation does the filter provide?
Attenuation is 60 dB or better from 10 kHz to 100 kHz and 60 dB or better from 100 kHz to 300 kHz. The partial discharge level is Q of 3 pC or less at rated voltage.
Can the filter be customised?
Yes. The rated capacity and the working voltage of the isolation filter can be customised to the customer requirement.

Reviewed by the Application Engineering Team at Nanjing Gaodian Electric Power Equipment

Specifications are taken from the manufacturer’s technical documentation. Final configuration and acceptance criteria follow the standard and edition you nominate — tell us your test list and we will confirm the ratings.

Related Products

Variable-Frequency Series Resonant Test System
High Voltage Test Equipment

Variable-Frequency Series Resonant Test System

Compact variable-frequency series resonant test system for AC withstand testing. Displays test data and status on a green screen with real-time operating prompts, and calculates the capacitance of the test object.

ECBZ-GD Energy-Efficient Transformer Energy-Grade Evaluation System
Transformer Testing

ECBZ-GD Energy-Efficient Transformer Energy-Grade Evaluation System

Automatic evaluation system for the energy-efficiency grade of distribution transformers up to 800 kVA at 10 kV/0.4 kV. Combines intelligent test sequence control, automatic wiring changeover, data processing, data upload and report generation in one bench.

YDTW Partial-Discharge-Free AC Test Transformer
High Voltage Test Equipment

YDTW Partial-Discharge-Free AC Test Transformer

Partial-discharge-free power-frequency test transformer for verifying the insulation level of insulating materials, insulation structures and electrical products, and as a PD-free power-frequency test supply for transformers, capacitors, HV switchgear, instrument transformers and surge arresters.

GD230 Ground Continuity Tester
Power Testing Instruments

GD230 Ground Continuity Tester

Portable instrument for measuring the continuity resistance between the grounding down conductors of individual items of equipment in a substation. Controlled by a high-performance MCU with automatic current selection, on-board data retention and a thermal printer.

Automatic AC Withstand Voltage Test Set
High Voltage Test Equipment

Automatic AC Withstand Voltage Test Set

GDNY-III automatic power-frequency withstand voltage test set, designed to the latest national industry test standards, for insulation strength tests on electrical products, components and insulating materials.

GD-300D Reactor Electrical Parameter Tester (Portable)
Reactor & Arc Suppression Coil Testing

GD-300D Reactor Electrical Parameter Tester (Portable)

Portable instrument dedicated to measuring the electrical parameters of single-phase and three-phase reactors, including AC phase voltage RMS, average voltage, current RMS, active power, reactance and inductance, at 0.5 class accuracy.

Need the datasheet for this model?

Send us this product name plus your test requirements. We reply with specifications, photos and a formal quotation.