High Voltage Test Equipment
Lightning Impulse Voltage Generator
Lightning impulse test system rated 400 kV / 20 kJ for distribution transformers, HV switchgear, ring main units, pole-mounted switchgear, disconnectors, circuit breakers and instrument transformers, with automatic gap adjustment and charging.

Overview
Lightning impulse test system rated 400 kV / 20 kJ for distribution transformers, HV switchgear, ring main units, pole-mounted switchgear, disconnectors, circuit breakers and instrument transformers, with automatic gap adjustment and charging.
Standards & Compliance
Benchmark standards for this equipment category
Systems in this category are commonly specified against these standards, linked to the issuing body. Final configuration and acceptance criteria follow the standard and edition you nominate.
- IEC 60060-1 — High-voltage test techniques - General definitions and test requirements
- IEC 60060-2 — High-voltage test techniques - Measuring systems
- IEC 60270 — Partial discharge measurements
- GB/T 16927.1 — High-voltage test techniques
- GB 7354 — Partial discharge measurement
Application Scenarios
Request Specifications & Quotation
Tell us your test object ratings, the test items you need and the applicable standards. Our sales engineers reply with a configuration proposal and a formal quotation within 24 hours.
Get a QuoteDetailed Description
Overview: the system performs lightning impulse tests on distribution transformers, high-voltage switchgear, ring main units, pole-mounted switchgear, disconnectors, circuit breakers and instrument transformers (CT/PT).
Construction: the system samples with an oscilloscope and a voltage divider, and is composed of a test transformer, capacitors, wave-front resistors, wave-tail resistors, a sphere gap and a chopping device. Rated voltage is 400 kV and rated energy is 20 kJ.
Control: the sphere gap is adjusted automatically and charging is automatic, with standardised waveform editing. Data is uploaded to the data centre platform through the control terminal.
Test capability: the lightning impulse test covers distribution transformers at 2500 kVA/10 kV, and high-voltage switchgear, ring main units, pole-mounted switchgear, circuit breakers, disconnectors and instrument transformers (CT/PT) at 35 kV.
Technical Specifications
| Rated voltage | 400KV |
|---|---|
| Rated energy | 20KJ |
| Test item | Lightning impulse test |
| Distribution transformer | 2500KVA/10KV |
| High-voltage switchgear | 35KV |
| Ring main unit | 35KV |
| Pole-mounted switchgear | 35KV |
| Circuit breaker | 35KV |
| Disconnecting switch | 35KV |
| Instrument transformer | 35KV |
Frequently Asked Questions
What is the Lightning Impulse Voltage Generator used for?
How is the system built and controlled?
How do I get a quotation?
Reviewed by the Application Engineering Team at Nanjing Gaodian Electric Power Equipment
Specifications are taken from the manufacturer’s technical documentation. Final configuration and acceptance criteria follow the standard and edition you nominate — tell us your test list and we will confirm the ratings.
Related Products

Variable-Frequency Series Resonant Test System
Compact variable-frequency series resonant test system for AC withstand testing. Displays test data and status on a green screen with real-time operating prompts, and calculates the capacitance of the test object.

ECBZ-GD Energy-Efficient Transformer Energy-Grade Evaluation System
Automatic evaluation system for the energy-efficiency grade of distribution transformers up to 800 kVA at 10 kV/0.4 kV. Combines intelligent test sequence control, automatic wiring changeover, data processing, data upload and report generation in one bench.

YDTW Partial-Discharge-Free AC Test Transformer
Partial-discharge-free power-frequency test transformer for verifying the insulation level of insulating materials, insulation structures and electrical products, and as a PD-free power-frequency test supply for transformers, capacitors, HV switchgear, instrument transformers and surge arresters.

GD230 Ground Continuity Tester
Portable instrument for measuring the continuity resistance between the grounding down conductors of individual items of equipment in a substation. Controlled by a high-performance MCU with automatic current selection, on-board data retention and a thermal printer.

Automatic AC Withstand Voltage Test Set
GDNY-III automatic power-frequency withstand voltage test set, designed to the latest national industry test standards, for insulation strength tests on electrical products, components and insulating materials.

GD-300D Reactor Electrical Parameter Tester (Portable)
Portable instrument dedicated to measuring the electrical parameters of single-phase and three-phase reactors, including AC phase voltage RMS, average voltage, current RMS, active power, reactance and inductance, at 0.5 class accuracy.
More in High Voltage Test Equipment
Need the datasheet for this model?
Send us this product name plus your test requirements. We reply with specifications, photos and a formal quotation.