Test Center Facilities
HV Test Center Central Control Room
Build specification for the central control room and machine room of a high-voltage test centre. Covers clear height, anti-static raised flooring with a minimum 100 mm void, reserved cable penetrations, glass curtain wall and air conditioning to a constant 20 ±5 ℃.

Overview
Build specification for the central control room and machine room of a high-voltage test centre. Covers clear height, anti-static raised flooring with a minimum 100 mm void, reserved cable penetrations, glass curtain wall and air conditioning to a constant 20 ±5 ℃.
Standards & Compliance
Benchmark standards for this equipment category
Systems in this category are commonly specified against these standards, linked to the issuing body. Final configuration and acceptance criteria follow the standard and edition you nominate.
- IEC 61010 — Safety requirements for electrical measuring equipment
- IEC 60060-2 — High-voltage test techniques - Measuring systems
- IEC 60270 — Partial discharge measurements
- GB/T 16927.1 — High-voltage test techniques
Application Scenarios
Request Specifications & Quotation
Tell us your test object ratings, the test items you need and the applicable standards. Our sales engineers reply with a configuration proposal and a formal quotation within 24 hours.
Get a QuoteDetailed Description
Central control room and machine room construction requirements: the test centre builds one central control room with an internal clear height of not less than 4 m. The floor is anti-static floor tile with a void of not less than 100 mm between the tile and the concrete floor, and five cable penetrations of 100 mm diameter are reserved between the raised floors of the control room and the machine room. The control room has a glass curtain wall and is air conditioned.
The test centre builds one machine room. The floor is anti-static floor tile with a void of not less than 100 mm above the concrete floor, and the machine room is air conditioned.
The room temperature meets the requirements of the relevant machine room standard, which is a constant 20 ±5 ℃.
Technical Specifications
| Central control rooms | 1 |
|---|---|
| Machine rooms | 1 |
| Internal clear height — control room | Not less than 4 m |
| Raised floor void | Not less than 100 mm above the concrete floor |
| Cable penetrations | 5 off, 100 mm diameter, between the control room and machine room raised floors |
| Partition | Glass curtain wall to the control room |
| Machine room temperature | Constant 20 ±5 ℃ |
| Air conditioning | Provided in both the control room and the machine room |
Frequently Asked Questions
How many rooms are built?
What are the flooring requirements?
What environmental conditions are required?
Further Reading
Method and selection guides that cover the tests this instrument performs.
Reviewed by the Application Engineering Team at Nanjing Gaodian Electric Power Equipment
Specifications are taken from the manufacturer’s technical documentation. Final configuration and acceptance criteria follow the standard and edition you nominate — tell us your test list and we will confirm the ratings.
Related Products

Artificial Rain Test Room
Construction specification for an artificial rain test zone, covering clear height, waterproofing of the roof and walls, seepage drainage with a ring drainage channel, mains water supply and 6 m³/h drainage, plus an anti-static control room with suspended ceiling, lighting and air conditioning.

ECBZ-GD Energy-Efficient Transformer Energy-Grade Evaluation System
Automatic evaluation system for the energy-efficiency grade of distribution transformers up to 800 kVA at 10 kV/0.4 kV. Combines intelligent test sequence control, automatic wiring changeover, data processing, data upload and report generation in one bench.

EMC Shielded Room for PD Testing
Modular bolted shielded enclosure built from 2 mm galvanised steel module plates with conductive gasketing, honeycomb waveguide ventilation, filtered power, dedicated grounding below 0.5 Ω and a double-glazed shielded observation window. Shielding effectiveness is 60 dB or better from 0.5 MHz to 1.6 MHz.

GD230 Ground Continuity Tester
Portable instrument for measuring the continuity resistance between the grounding down conductors of individual items of equipment in a substation. Controlled by a high-performance MCU with automatic current selection, on-board data retention and a thermal printer.

GD-300D Reactor Electrical Parameter Tester (Portable)
Portable instrument dedicated to measuring the electrical parameters of single-phase and three-phase reactors, including AC phase voltage RMS, average voltage, current RMS, active power, reactance and inductance, at 0.5 class accuracy.

GD-300D Reactor Electrical Parameter Tester (Built-in)
Panel-mounted version of the GD-300D reactor electrical parameter tester, using a 320 x 240 dot-matrix LCD with multi-screen menu operation and direct measurement of three-phase reactance, inductance and total active power.
More in Test Center Facilities
Need the datasheet for this model?
Send us this product name plus your test requirements. We reply with specifications, photos and a formal quotation.