Material Sampling Test Systems
Automatic Instrument Transformer (CT/PT) Test System
Human-machine terminal and integrated test device for sampling tests on instrument transformers rated 35 kV and below. Automatically drives the measurement, power and switching modules item by item, then generates the test report and uploads data to the data-centre platform.

Overview
Human-machine terminal and integrated test device for sampling tests on instrument transformers rated 35 kV and below. Automatically drives the measurement, power and switching modules item by item, then generates the test report and uploads data to the data-centre platform.
Standards & Compliance
Benchmark standards for this equipment category
Systems in this category are commonly specified against these standards, linked to the issuing body. Final configuration and acceptance criteria follow the standard and edition you nominate.
- IEC 61869-1 — Instrument transformers - General requirements
- IEC 61869-2 — Additional requirements for current transformers
- IEC 60270 — Partial discharge measurements
- GB 1207 — Voltage transformers
- GB 1208 — Current transformers
- DL/T 845 — Loop resistance testing
Application Scenarios
Request Specifications & Quotation
Tell us your test object ratings, the test items you need and the applicable standards. Our sales engineers reply with a configuration proposal and a formal quotation within 24 hours.
Get a QuoteDetailed Description
System overview: the system covers sampling tests on instrument transformers rated 35 kV and below.
Configuration: the system is a human-machine interface terminal with an integrated test device. The test device contains an intelligent measurement module, a power distribution module, an automatic wiring-changeover module and a wiring indication module.
Operation: the system automatically calls the intelligent measurement module, the power module and the switching device and starts testing item by item, automatically completing the voltage and current output, parameter measurement, range switching and data upload for every test item.
Data handling: the system receives test tasks automatically, generates the test report automatically and uploads the data to the data-centre platform.
Technical Specifications
| Applicable voltage class | 35 kV and below |
|---|---|
| Applicable test objects | Instrument transformers (CT/PT) |
| Configuration | Human-machine interface terminal with integrated test device |
| Test device modules | Intelligent measurement, power distribution, automatic wiring changeover, wiring indication |
| Data handling | Automatic task reception, automatic report generation, upload to the data-centre platform |
Frequently Asked Questions
What voltage class does the instrument transformer test system cover?
What modules make up the test device?
How is the test sequence executed?
Further Reading
Method and selection guides that cover the tests this instrument performs.
Reviewed by the Application Engineering Team at Nanjing Gaodian Electric Power Equipment
Specifications are taken from the manufacturer’s technical documentation. Final configuration and acceptance criteria follow the standard and edition you nominate — tell us your test list and we will confirm the ratings.
Related Products

Automatic Switchgear Comprehensive Test System
Human-machine terminal and integrated test device for sampling tests on high-voltage switchgear, ring main units, pole-mounted switchgear, disconnectors, cable branch boxes and low-voltage switchgear. Runs loop resistance and mechanical characteristic tests on one-key start and performs unattended automatic temperature-rise testing.

ECBZ-GD Energy-Efficient Transformer Energy-Grade Evaluation System
Automatic evaluation system for the energy-efficiency grade of distribution transformers up to 800 kVA at 10 kV/0.4 kV. Combines intelligent test sequence control, automatic wiring changeover, data processing, data upload and report generation in one bench.

Automatic Surge Arrester Comprehensive Test System
Human-machine terminal and integrated test device for sampling tests on surge arresters rated 35 kV and below. A single connection completes the power-frequency reference voltage, continuous current, DC reference voltage and 0.75 times DC leakage current tests.

GD230 Ground Continuity Tester
Portable instrument for measuring the continuity resistance between the grounding down conductors of individual items of equipment in a substation. Controlled by a high-performance MCU with automatic current selection, on-board data retention and a thermal printer.

GDFA-105 CT/PT Comprehensive Tester
Dedicated instrument for testing current and voltage transformers in relay protection and high-voltage insulation work. Automatically plots volt-ampere characteristics and 5% or 10% error curves, and performs ratio and polarity testing.

GD-300D Reactor Electrical Parameter Tester (Portable)
Portable instrument dedicated to measuring the electrical parameters of single-phase and three-phase reactors, including AC phase voltage RMS, average voltage, current RMS, active power, reactance and inductance, at 0.5 class accuracy.
Need the datasheet for this model?
Send us this product name plus your test requirements. We reply with specifications, photos and a formal quotation.