High Voltage Test Equipment

YDTW Partial-Discharge-Free AC Test Transformer

Low partial-discharge AC test transformer used to verify the power-frequency insulation level of insulating materials, insulation structures and electrical products, and to serve as a PD-free test source for transformers, capacitors, HV switches, instrument transformers and surge arresters. Its own partial discharge level is kept low enough not to mask the discharge signal of the test object.

YDTW Partial-Discharge-Free AC Test Transformer
Standards
IEC 60060-1 · GB/T 16927.1 · GB/T 7354
Applications
PD-free withstand test · Insulation level verification · Research institute & university

Overview

Low partial-discharge AC test transformer used to verify the power-frequency insulation level of insulating materials, insulation structures and electrical products, and to serve as a PD-free test source for transformers, capacitors, HV switches, instrument transformers and surge arresters. Its own partial discharge level is kept low enough not to mask the discharge signal of the test object.

Applicable Standards

  • IEC 60060-1
  • GB/T 16927.1
  • GB/T 7354

Application Scenarios

PD-free withstand testInsulation level verificationResearch institute & university

Request Specifications & Quotation

Tell us your test object ratings, the test items you need and the applicable standards. Our sales engineers reply with a configuration proposal and a formal quotation within 24 hours.

Get a Quote

Frequently Asked Questions

What is a partial-discharge-free test transformer?
It is an AC test transformer whose own internal partial discharge level is low enough that it does not mask the discharge signal coming from the equipment under test. It acts as a clean power-frequency high-voltage source, not as a partial discharge measuring instrument.
What is it used for?
It verifies the power-frequency insulation level of insulating materials, insulation structures and finished products, and serves as the PD-free source for withstand and partial discharge tests on transformers, capacitors, HV switches, instrument transformers and surge arresters.
How does this differ from a partial discharge detector?
A partial discharge detector measures the discharge signal of the test object. A partial-discharge-free test transformer supplies the high voltage without contributing measurable discharge of its own. Both are needed in a PD test circuit — they are not substitutes for each other.

Need the datasheet for this model?